Gilera 150 Dynamo & Regulator

Forum für klassische und neue Gilera-Motorräder
Bulletin Board for classic and new Gilera-Motorcycles

Moderator: Joachim

Post Reply
DMess
Tank-Reserve-Benutzer
Posts: 5
Joined: Mon Nov 07, 2022 10:19 am

Gilera 150 Dynamo & Regulator

Post by DMess » Mon Nov 28, 2022 8:30 pm

Gilera Dynamo 20221128_170824.jpg
Ok I've got the bike up and running but I'm getting high voltage from the Dynamo/Regulator +10V, the picture shows how its currently wired. I cant see how this would work as the DF & D+ wires are coming straight off the dynamo terminals 51 & 61 in effect not going through the regulator?!

Does anyone know if this is correct, if it is correct and the regulator is not working has anyone fitted a solid state regulator?

Getting closer to being able to ride it :D :D

Thanks,

Dave
You do not have the required permissions to view the files attached to this post.

Post Reply